Important information about design standards

We are in the process of updating the documents below. Please visit the Supplier Portal for the most up to date documents.

We maintain standards in a number of areas to record our best practice and ensure consistency in the design of our assets. Access key standards and specifications here.

The following standards are primarily used by Design Engineers to produce designs and contract documents that deliver acceptable assets.

It is common for standards and product specifications to be referenced in our tender and contract documents. We have made the copies of our standards, specifications and drawings available to assist contractors who are submitting tenders, by providing easier access to the documents.

We will still be maintaining the access to our standards through our eProcurement portal for 'Registered standards' copy holders. Registered copy holders will have the same version as on the public website but will be notified by email when any changes are made to a document.

Please note: Water Corporation Design Standards should be used in conjunction with the Water Services Association of Australia (WSAA) Codes. We recommend that you purchase a copy of the Codes from the WSAA online bookshop.

Disclaimer

Please read the following disclaimer before referencing these documents.

Any person or entity which relies upon the Standards/Specifications from the Water Corporation website does so entirely at their own risk and without any right of recourse to the Water Corporation, including, but not limited to, using the Standards/Specification for works other than for or on behalf of the Water Corporation. The Standards/Specifications available from the Water Corporation website are intended solely for information only and cannot be relied upon. The Water Corporation accepts no liability for any loss or damage that arises from anything in the Standards/Specifications including (but not limited to) any loss or damage that may arise due to the errors and omissions of any person.

The Water Corporation shall not be responsible, nor liable, to any person or entity for any loss or damage suffered as a consequence of reliance on, or the unlawful use of, or reference to, the Standards/Specifications, including but not limited to the use of any part of the Standards/Specification without first obtaining prior express written permission from the CEO of the Water Corporation.

Any interpretation of anything in the Standards/Specifications that deviates from specific Water Corporation Project requirements must be referred to the Water Corporation’s project manager and/or designer for that particular Project for further direction or agreement.

 

Standards, specifications and drawings

Document downloads for electrical standards
Downloads

DS20 Design Process for Electrical Works Ver2Rev7

DS21 Major Pump Station Electrical Ver1Rev7
DS22 Ancillary Plant and Small Pump Stations Electrical Ver1Rev6
 DS23 Pipeline AC Interference and Substation Earthing Ver1Rev4
 DS24 Electrical Drafting Ver0Rev2
 DS25 – Solar Energy Systems Ver1 Rev0

 DS26 – Type Specifications Electrical Index Ver1 Rev6

 DS28 – Water and Wastewater Treatment Plants Electrical Ver1 Rev7
 DS29 – Arc Flash Hazard Assessment Ver1 Rev2
 Electrical Preferred Equipment List
 Major Pump Station Standard Electrical Drawings
 Small Pump Station Standard Electrical Drawings - MN01
 Small Pump Station Standard Electrical Drawings - Superceded
 Switchboard Manufacturers Panel Information for Use of Panel
 Switchboard Manufacturers Panel Details Summary Ver1 Rev5

Caption describing what the table is about for screen readers
Downloads
Preferred Equipment List for Chlorine Systems
DS70-01 - Chlorine Buildings Ver1 Rev3
DS70-02 - Chlorine Leak Detectors Ver1 Rev3
DS70-03 - Emergency Shutoff Device for use on Chlorine Containers Ver1 Rev4
DS70-05 - Chlorine Container Floor Scales Ver1 Rev2
 DS70-20 - Small Chlorination Systems Water Control Function Description Ver4 Rev14
DS70-20/30 -  Small Chlorination Systems (Water) - Basis of Design Ver1 Rev0
 DS70-25 Drum Sequenced Vacuum System Functional Control Description
 DS70-25 Drum Sequenced Vacuum System Functional Description Overview
 DS70-30 - Small Chlorination Systems Wastewater Control Function Description Ver1 Rev2

DS71-01 - Fluoro Acid Storage (FSA) Storage and Dosing Facilities Ver2 Rev3

 DS71-02 - Fluorosilicic Acid Storage and Dosing System Control Functional Specification Ver1 Rev1

 DS71 - Drawing List Fluorosilicic Acid Standard Designs
 DS72-01 - Lime Storage Mixing and Dosing System Basis of Design Ver1 Rev0
 DS72-02 - Lime Storage Mixing and Dosing System Control Functional Specification Ver1 Rev0

 DS73-01 - Bulk Sodium Hypochlorite Storage and Dosing System Basis of Design Ver1 Rev0

 DS73-02 - Bulk Sodium Hypochlorite Storage and Dosing System Control Functional Specification Ver1 Rev0

 DS79 - Design of Chemical Systems Legislative Requirements and General Principles Ver2 Rev0 
 DS79-02 - Emergency Safety Showers and Eyewash Stations Ver2 Rev0
 DS79-03 - Chemical Barrier Protection Ver1 Rev1
 DS 79-04 Chemical Signage, Labelling and Markers Ver1Rev0
 Chemical Facility Operations Equipment Specification - Cylinder Ramps
 Chemical Facility Operations Equipment Specification - Manifest Holder Tube
 Chemical Facility Operations Equipment Specification - Portable Eyewash Unit
 Chemical Facility Operations Equipment Specification - SCBA Cabinet Wall or Vehicle Mounted 
 Chemical Facility Operation Equipment Specification - Windvane Assembly
 Chlorination Facility Operations Equipment Specification - Chlorine Mallet
 Chlorination Facility Operations Equipment Specification - Chlorine Pigtails Copper Flexible Tubing
 Chlorination Facility Operations Equipment Specification - Chlorine Washers
 Chlorination Facility Operations Equipment Specification - ChlorineValve Key 
 Chlorination Facility Operations Equipment Specification - Multi Chlorine Spanner
 Chlorination Facility Operations Equipment Specification - Single Ammonia Bottle Station
 Chlorination Facility Operations Equipment Specification - Windsock Assembly 

 

Caption describing what the table is about for screen readers
Downloads
DS Corrosives multi PPE mandatory safety signage spec
DS WCSS001–1 Hazchem placard
DS WCSS002–1 Chlorine Bulk Transport EIP
DS WCSS002–2 Chlorine Bulk placard
DS WCSS002–3 Chlorine Package placard
 DS WCSS002–4 Chlorine Bulk & Package Transport labels
 DS WCSS003–1 Sodium Hypochlorite Bulk Transport EIP
 DS WCSS003–2 Sodium Hypochlorite Bulk placard
 DS WCSS003–3 Sodium Hypochlorite Package placard
 DS WCSS003–4 Sodium Hypochlorite Transport Class label
 DS WCSS005–1 Calcium Hypochlorite Bulk placard
 DS WCSS005–3 Calcium Hypochlorite Bulk Transport EIP
 DS WCSS005–4 Calcium Hypochlorite Transport label
 DS WCSS006–0 Corrosive Liquid NOS Citric Acid Bulk placard
 DS WCSS006–1 Corrosive Liquid Acidic Inorganic NOS Bulk placard
 DS WCSS006–2 Corrosive Liquid Acidic Organic NOS Bulk placard
 DS WCSS006–3 Corrosive Liquid Basic Inorganic NOS Bulk placard
 DS WCSS006–4 Corrosive Liquid Basic Organic NOS Bulk placard
 DS WCSS006–5 Corrosive Liquid Acidic Inorganic NOS Contains Ferric Sulphate Bulk
 DS WCSS006–6 Corrosive Liquid Basic Organic NOS Contains EDTA & Salts Bulk 
 DS WCSS006–7 Corrosive Chemicals Transport Class label
 DS WCSS006–8 Corrosive Liquid NOS Contains Sulphamic Acid Bulk placard
 DS WCSS006–9 Corrosive Liquid NOS Contains Oxalic Acid 10% Bulk placard
 DS WCSS007–1 Hydrochloric Acid Bulk Transport EIP
 DS WCSS007–2 Hydrochloric Acid Bulk placard
 DS WCSS007–3 Hydrochloric Acid Package placard
 DS WCSS008–1 Sodium Hydroxide Caustic Soda Bulk Transport EIP
 DS WCSS008–2 Sodium Hydroxide Caustic Soda Bulk Store placard
 DS WCSS008–3 Sodium Hydroxide Caustic Soda Package Store placard
 DS WCSS009–1 Ferric Chloride Bulk placard
 DS WCSS009–2 Ferric Chloride Solution Package placard
 DS WCSS010–1 Sodium Metabisulphite Bulk placard
 DS WCSS010–2 Sodium Metabisulphite Package placard
 DS WCSS011–1 Sodium Bisulphite Solution Bulk placard 
 DS WCSS011–2 Sodium Bisulphite Package placard
 DS WCSS012–1 Carbon Dioxide Bulk placard
 DS WCSS012–2 Carbon Dioxide Package placard
 DS WCSS013–1 Sodium Fluoride Bulk placard
 DS WCSS013–2 Sodium Fluoride Package placard
 DS WCSS014–1 Potassium Permanganate Bulk placard
 DS WCSS014–2 Potassium Permaganate Package placard
 DS WCSS015–1 Fluorosilicic Acid FSA Bulk placard
 DS WCSS015–2 Fluorosilicic Acid FSA Package placard
 DS WCSS016–1 Sodium Fluorosilicate Package placard
 DS WCSS016–2 Sodium Fluorosilicate Bulk placard
 DS WCSS017–1 Sulphamic Acid Powder Package placard
 DS WCSS017–2 Sulphamic Acid Bulk placard
 DS WCSS018–1 Petrol Bulk placard
 DS WCSS018–2 Petrol Transport and Tan Class label
 DS WCSS018–3 Petrol Package placard
 DS WCSS019–1 Ammonia Anhydrous Liquefied Bulk placard
 DS WCSS019–2 Ammonia Anhydrous Liquefied Bulk Transport EIP
 DS WCSS019–3 Ammonia Anhydrous Package placard
 DS WCSS020–1 Liquid Petroleum Gas LPG Package placard
 DS WCSS021–1 Aqueous Ammonia Bulk placard
 DS WCSS021–2 Aqueous Ammonia Package placard
 DS WCSS022–1 Sulphuric Acid 98% Bulk placard
 DS WCSS022–2 Sulphuric Acid Package placard
 DS WCSS022–3 Sulphuric Acid 34% Bulk placard
 DS WCSS023–1 Combustible Liquid placard
 DS WCSS024–1 Mixed Class Package placard 
 DS WCSS024–2 Mixed Corrosive Class Package placard
 DS WCSS024–3 Mixed Corrosive Example Bulk placard
 DS WCSS025–1 Hydrogen Peroxide Bulk placard
 DS WCSS025–2 Hydrogen Peroxide Package placard
 DS WCSS026–1 Air Compressed Bulk placard 
 DS WCSS026–2 Air Compressed Package placard
 DS WCSS026–3 Oxygen Gas Cylinder Package placard
 DS WCSS026–4 Acetylene Gas Package placard 
 DS WCSS026–5 Nitrogen Compressed Bulk placard
 DS WCSS026–6 Nitrogen Compressed Package placard
 DS WCSS027–1 Package Store Example sign
 DS WCSS050–1 Hydrated Lime Facility sign
 DS WCSS050–2 Hydrated Lime Silo sign
 DS WCSS050–3 Lime Silo Fill Point sign 
 DS WCSS050–4 Milk of Lime sign
 DS WCSS050–5 Lime Putty Tank sign
 DS WCSS051–1 Soda Ash Store sign 
 DS WCSS051–2 Soda Ash Solution Tank sign
 DS WCSS051–3 Soda Ash Container sign
 DS WCSS051–4 FSA Waste Drum sign 
 DS WCSS052–1 Citric Acid Store sign
 DS WCSS052–2 Citric Acid Solution Tank sign
 DS WCSS053–1 Aluminium Sulphate Store sign 
 DS WCSS053–2 Aluminium Sulphate Tank sign 
 DS WCSS054–1 Polyaluminium Chloride Store sign
 DS WCSS054–2 Polyaluminium Chloride Tank sign 
 DS WCSS054–3 Aluminium Chlorohydrate Store sign
 DS WCSS054–4 Aluminium Chlorohydrate Tank sign
 DS WCSS055–1 Corrosive Chemical Waste Tank sign
 DS WCSS055–2 Corrosive Chemical Solution sign 
 DS WCSS056–1 Calcium Hypochlorite Chamber sign
 DS WCSS057–1 Sodium Fluorosilicate Solution Tank sign
 DS WCSS057–2 Sodium Fluoride Saturator Tank sign
 DS WCSS058–1 Ferric Sulphate Facility sign
 DS WCSS058–2 Ferric Sulphate Tank sign
 DS WCSS059–1 Anti Scalant Facility sign
 DS WCSS059–2 Anti Scalant Tank sign
 DS WCSS060–1 Powder Activated Carbon Store sign
 DS WCSS062–2 Toxic Chemical Waste Tank sign
 DS WCSS075–1 Calgon Facility sign 
 DS WCSS075–2 Calgon Solution Tank sign
 DS WCSS076–1 Polyelectrolyte Facility sign
 DS WCSS076–2 Polyelectrolyte Solution Tank sign
 DS WCSS076–3 Polyelectrolyte Store sign
 DS WCSS077–1 Coagulant Aid Facility sign
 DS WCSS077–2 Coagulant Aid Tank sign 
 DS WCSS078–1 Sodium Nitrate Bulk placard
 DS WCSS078–2 Sodium Nitrate Package placard
 DS WCSS079–1 Sodium Aluminate Bulk placard
 DS WCSS079–2 Sodium Aluminate Package placard
 DS WCSS101 Multi Chlorine sign
 DS WCSS102 & Gantry Crane Isolation sign
 DS WCSS103 & Multi Fluorosilicic Acid sign
 DS WCSS104 Flammable Liquid sign
 DS WCSS105 & Combustible Liquid sign
 DS WCSS106 Multi Calcium Hypochlorite sign 
 DS WCSS107 Flammable Gas sign
 DS WCSS108 Multi Sodium Hypochlorite sign
 DS WCSS109 Multi Sodium Hydroxide Caustic Soda sign 
 DS WCSS110 Multi Sodium Metabisulphite sign
 DS WCSS111 Multi Sulfuric Acid sign
 DS WCSS112 Multi Ferric Chloride sign
 DS WCSS113 Multi Sodium Bisulphite sign
 DS WCSS114 Multi Ferric Sulphate sign
 DS WCSS115 Auto Start Dosing Equipment sign
 DS WCSS116 Multi Ammonia Anhydrous sign
 DS WCSS117 Multi Corrosive Chemicals sign 
 DS WCSS118 Multi Sodium Fluorosilicate sign
 DS WCSS119 No Chemical Delivery sign
 DS WCSS120 Chlorine Red Light sign
 DS WCSS121 Flammable Liquid Cabinet sign
 DS WCSS122 Multi Ammonia Aqueous sign
 DS WCSS123 Multi Carbon Dioxide sign
 DS WCSS124 Multi Hydrochloric Acid sign
 DS WCSS125 Multi Hydrogen Peroxide sign
 DS WCSS126 Multi Nitric Acid sign 
 DS WCSS127 Multi Sodium Fluoride sign
 DS WCSS128 Multi Sulphamic Acid sign
 DS WCSS129 Trade Waste Pit Sign
 DS WCSS131 Danger No Chlorine Leak Warning 
 DS WCSS132 Multi Sodium Aluminate sign
 DS WCSS133 Multi Sodium Nitrate sign 
 DS WCSS150 Door Open sign 
 DS WCSS151 Fans Operation sign
 DS WCSS152 Chlorine Vacuum sign 
 DS WCSS153 Emergency Exercise Simulation sign
 DS WCSS154 Buried Chemical Line sign
 DS WCSS156 Chemical Line sign
 DS WCSS157 Buried Service Duct sign
 DS WCSS160 Commissioning sign
 DS WCSS161 Chlorine Buffer No Entry sign
 DS WCSS164 Chlorine Roller Door sign
 DS WCSS166 Chlorine Solution Dosing sign 
 DS WCSS167 Chemical Acid Waste Tank sign 
 DS WCSS169 Chemical Waste Tank Valve sign
 DS WCSS170 Chlorine Vent Line sign
 DS WCSS171 Warning Chlorine Work in Progress
 DS WCSS172 Valve Locked in Closed Position
 DS WCSS200 Safety Goggles sign
 DS WCSS201 Safety Dust Mask sign
 DS WCSS202 Safety Face Shield sign
 DS WCSS203 Double Eye Protection Must be Worn sign
 DS WCSS251 No Entry Authorised Personnel Only sign
 DS WCSS252 No Vehicle Entry sign
 DS WCSS253 Stop No Entry Chemical Delivery sign
 DS WCSS254 No Entry Operations Area sign
 DS WCSS255 Non Potable Water sign 
 DS WCSS300 Emergency Assembly Point sign
 DS WCSS301 Emergency Manifest sign 
 DS WCSS302 Emergency Manifest Tube label
 DS WCSS302–1 ESM Tube label
 DS WCSS302–2 ERP Tube label
 DS WCSS303 Emergency Response Plan ERP sign
 DS WCSS304 Emergency Services Manifest and Emergency Response Plan sign 
 DS WCSS305 Self Contained Breathing Apparatus sign
 DS WCSS306 Emergency Shower and Eyewash sign
 DS WCSS307 Emergency Shower Direction sign
 DS WCSS308 Emergency Eyewash sign
 DS WCSS309 Emergency Door Exit Only sign
 DS WCSS310 Evacuation Information sign
 DS WCSS325 Fire Extinguisher sign
 DS WCSS350 Test Safety Shower sign
 DS WCSS351 First Aid Station sign
 DS WCSS352 Personal Protective Equipment sign
 DS WCSS354 Test Safety Shower Prior to Work sign 
 DS WCSS400 1 2 3 4 Chemical Container or Equipment Status labels
 DS WCSS401 Room Identification labels 
 DS WCSS402 Maximum Fill label
 DS WCSS403 Process Unit Identification labels
 DS WCSS404 Tank Silo Number and Volume labels
 DS WCSS406 Faulty Chlorine Container label
 DS WCSS451 Chlorine Gas Small Pipe Marker
 DS WCSS452 Large Chemical Pipeline Marker
 DS WCSS453 Standard Colour Coding for Pipe Work
 DS WCSS454 Small Chemical Pipeline Marker
 DS WCSS500 Chlorine Security Fan sign
 DS WCSS501 Regional Module Security sign
 DS WCSS502 Metro Module Security sign
 DS WCSS525 Visitors Parking sign
 DS WCSS526 Plant Entry Name signs
 DS WCSS600 Visitors Report sign
 DS WCSS601 Bore Testing sign
 DS WCSS602 No Entry Disabled Door sign
 DS WCSS603 No Exit Disabled Door sign
 DS WCSS650 Multi Chemical Deliveries sign
 DS WCSS651 Chemical Deliveries sign
 DS WCSS652 Remote Site Direction sign
 Typical signage Layout for a Chlorine Module 
 Typical signage Layout for Chlorine & FSA Buildings

Caption describing what the table is about for screen readers
Downloads
DS80 – WCX CAD Ver7 Rev2

Caption describing what the table is about for screen readers
Downloads
Concrete Structures Condition Assessment Guideline Ver2 Rev0
CR5 – Application of Chemical Resistant Protective Coating on Concrete Bunds in Water and Wastewater Treatment Plants Issue2
DS91 – Selection Design and Monitoring of Cathodic Protection Systems Ver3 Rev0
DS95 – Standard for Selection Preparation Application Inspection and Testing of Protective Coatings on Water Corporation Assets Ver2 Rev0
DS95 Standard for Selection, Preparation, Application, Inspection and Testing of Protective Coatings on Water Corporation Assets – Bulletin 17-01
 A1 – Surface Preparation for the Application of Protective Coatings on Steel or Cast Iron Ver2
 A2 – Surface Preparation for the Application of Protective Coatings on Stainless Steel Ver2
 A3 – Surface  Preparation for the Application of Protective Coatings on Galvanised Steel Ver2
 A4 – Surface  Preparation for the Application of Protective Coatings on Aluminium Ver2
 A5 – Surface Preparation for the Application of Protective Coatings on Concrete Ver2
 A6 – Surface Preparation for the Application of Protective Coatings on Plastics Ver2
 A7 – Surface Preparation for the Application of Protective Coatings on Fusion Bonded Polyethylene Sintakote® Ver2
 B1 – Inorganic Zinc Silicate Coating on Steel or Cast Iron Ver2
 B2 – Inorganic Zinc Silicate Epoxy Primer Tie Coat Acrylic Top Coating on Steel or Cast Iron Ver2
 C1 – Zinc Rich Epoxy Primer Coating on Steel or Cast Iron Ver2
 C2 – Zinc Rich Epoxy Primer Epoxy Mastic Coat Polyurethane Top Coat on Steel or Cast Iron Ver2
 C3 – Zinc Rich Epoxy Primer Epoxy Mastic Coat on Steel or Cast  Iron Ver2 
 C4 – Zinc Rich Epoxy Primer Polyurethane Top Coat on Steel or Cast Iron Ver2
 D1 – High Build Epoxy Coating on Steel or Cast Iron Ver2
 D2 – High Build Epoxy Coating on Butterfly Valves Ver2
 D3 – High Build Epoxy Coating on New Old Concrete Ver2
 D4 – Ultra High Build Epoxy Coating on Steel or Cast Iron Ver2
 E1 – Epoxy Masting Coating on Steel or Cast Iron Ver2
 E2 – Epoxy Mastic Coating on Non Return Control Valves New and Existing Valves Ver2
 E3 – Epoxy Mastic Polyurethane Top Coat on Steel or Cast Iron Ver2
 E4 – Epoxy Mastic Polyurethane Top Coat on Galvanised Steel Ver2
 E5 – Epoxy Mastic Polyurethane Top Coat on Fusion Bonded Polyethylene Sintakote Ver2
 F1 – Glass Flake Epoxy Mastic Coating Ver1
 F2 – High Build Ceramic Filled Epoxy Coating on Existing Control Valves Ver1
 F3 – High Build Ceramic Filled Epoxy Coating on New and Existing Pumps Ver1
 G1 – Thermostatically Applied Polyester Powder Coating For Aluminium Sheet Metal Cabinets Ver2
 G2 – Thermal Bonded Polymeric Coating On Valves And Fittings For Water Industry Purposes Ver1
 H1 – Repair of Galvanised Coating Ver2
 H2 – Galvanised Coating of Steel Structures Ver2
 H3 – Repair of Inorganic Zinc Silicate (IZS) Coated Structures Ver1
 I1 – Elastomeric Polyurethane Protective Coating on Concrete Ver1
 J1 – Anti Graffiti Coating on New and Old Steel Structures Ver1
 J2 – Anti Graffiti Coating on New and Old Concrete  Structures Ver1
 K1 – Aesthetic Finish Coating on above Ground PVC Pipes and Fittings Ver1
 L1 – Tape Wrapping Procedure Ver1
 L2 – Heat Shrink Sleeve Ver 3
 M1 – Coating Procedure for Pipe Transition Below to Above Ground Ver1
 M2 – Coating Procedure for Sintakote Pipe and Steel Pipe Joints Ver1
 M3 – Coating Procedure for Clean Skin Pipe Permanently Exposed to Atmosphere Ver1
 M4 – Coating Procedure for Coupling Jointed Pipes Ver1 
 M5 – Coating Procedure for Steel Pipe at the Concrete Interface Ver1 
 M6 – Coating Procedure for Sintakote Pipe at the Concrete Interface Ver1 
 M7 – Coating Procedure on Galvanised Steel for the Decorative Purposes Ver1
 M8 – Cement Mortar Lining Requirement Ver1
 M9 – Grouting Convex Band in Pipelines Ver1
 FRP/GRP Structural Material Specification Ver1
 Inspection Guidelines for Condition Assessment of Concrete and Steel Structures Using Unmanned Aerial Vehicles UAVs Ver2 Rev0
 Steel Tanks Condition Assessment Guideline Ver2 Rev0
 WP – Plastic Lining Welding Audit RevB
 WS 1 – Metal Arc Welding Ver1 Rev8
 WS 2 – Welding Joining Specification Thermoplastics Ver1 Rev5

Caption describing what the table is about for screen readers
Downloads
Pipeline Selection Guideline

Caption describing what the table is about for screen readers
Downloads
Strategic Product Supply Submission Guidelines Ver1 Rev2
Strategic Products Register Ver3 Rev3

Caption describing what the table is about for screen readers
Downloads
SPS100 – Steel Pipe for Waterworks Purposes Ver0 Rev8
SPS106 – Ductile Iron Pipe Fittings for Pressure Applications Ver2Rev3
SPS115 – Unplasticised Polyvinylchloride PVCU Pipe for Pressure Applications Ver1 Rev1
SPS116 – Modified Polyvinylchloride PVCM Pipe for Pressure Applications Ver1Rev1
SPS117 – Oriented Polyvinylchloride PVCO Pipe Ver1Rev0
SPS125 – Polyethylene and Polypropylene Pipe and Pipe Fittings Ver1 Rev3
SPS130 – Glass Reinforced Plastics Pipe and Pipe Fittings Ver1Rev1
SPS152 – Stainless Steel Repair Clamps for Waterworks Pipes Ver0 Rev5
SPS155 – Metered Standpipes Ver0 Rev3
SPS200 – Air Valves for Water Supply Ver2 Rev0
SPS201 – Air Valves for Sewerage Ver2 Rev0
SPS214 – Double Check Valves Ver1 Rev0
SPS215 – Reduced Pressure Zone Devices Ver1 Rev0 
SPS220 – Metallic Non Return Valves Ver1 Rev4
SPS223 – Ductile Iron Swing Check Non Return Valves Ver1 Rev3
SPS226 – Dual Plate Non Return Valves Ver1 Rev3 
SPS230 – Rapid Response Non Return Valves Ver1 Rev1
SPS240 – Hydraulically Operated Automatic Control Valves Ver2 Rev1
SPS241 – Inline (Axial) Control Valves Ver1 Rev1
SPS245 – Vacuum Interface Valves Ver3 Rev1
SPS249 – Bladder Surge Vessels Ver1 Rev3 
SPS250 – GRP Filter Vessels Ver1 Rev0
SPS251 – Mains Tapping Ball Valves Ver4 Rev2
SPS252 – Metallic Ball Valves for General Purposes Ver2 Rev4
SPS254 – Meter Ball Valves Ver1 Rev5
SPS255 – Copper Alloy Gate Valves Ver2 Rev2
SPS259 – Knife gate Valves Ver1 Rev2 
SPS260 – Butterfly Valves for General Purposes Ver2 Rev1 
SPS261 – Butterfly Valves for Waterworks Purposes Ver 5 Rev4
SPS262 – High Performance Butterfly Valves Ver1 Rev7
SPS263 – Butterfly Guard Valves Ver2 Rev0
SPS263 – Advice to users of DS30 Design Standards
SPS271 – Gate Valves for Waterworks Purposes Metal Seated Ver6 Rev3
SPS272 – Gate Valves for Waterworks Purposes Resilient Seated Ver5 Rev3
SPS292 – Screw Down Fire Hydrants Ver1 Rev2
SPS295 – Penstocks for Waterworks Purposes Ver1 Rev3
SPS300 - Water Meters - DN20 - Ver6 Rev5
SPS479 – Polyethylene Tanks for Chemical Service
SPS498 – GRP Chemical Storage Tanks Ver1 Rev0
SPS500 – ISO End Suction Centrifugal Pumps Ver1 Rev0
SPS501 – End Suction Centrifugal Motor Pumps Ver1 Rev0
SPS503 – Submersible Sewage Pumps Ver2 Rev3
SPS506 – Vertical Multi stage Electric Centrifugal Pumps Ver1 Rev0
SPS507 – Multistage Submersible Electric Borehole Pumps Ver2 Rev0
SPS515 – Axially Split Casing Centrifugal Pumps Ver2 Rev1
SPS525 – Progressive Cavity Pumps Ver1 Rev1
SPS700 – Precast RC Access Chambers Ver1 Rev0
SPS702 – Precast Concrete Wastewater Pumping Stations Ver1 Rev0 (PDF - 1.6MB)
SPS801 – Access Covers for General Purposes Ver1 Rev1
SPS802 – Prototype Assisted Lift Access Covers Ver1 Rev1

Caption describing what the table is about for screen readers
Downloads
Safety in design guideword checklist
Safety in design report template
Safety in design work instruction

More information

For general enquiries please contact engineering.standardsenquiries@watercorporation.com.au